Vacutest Kima K2EDTA haematology tubes, 1 ml, 13 × 75 mm

In stockDelivery in 24–48h

44,77 lei VAT incl.37,00 lei + VAT

44,77 lei/box

In stock

Large quantity? Request a quote

  • Delivery 20 lei + VAT (24,20 lei VAT incl.), free from 300 lei + VAT
  • Minimum order 150 lei + VAT
  • Invoice with tax ID and payment by bank transfer
  • Product sealed for health protection/hygiene reasons: the right of withdrawal is lost if you unseal it after delivery. This exception does not affect your rights for a product that is not in conformity. Right of withdrawal
  • Your legal guarantee rights (2 years)

Legal guarantee of conformity

Legal guarantee: the harmonised notice of the European Union, with a QR code to the Your Europe portal. The full text is below.

More information on your rights: europa.eu/youreurope/guarantees
Open the notice at full size

Text of the notice

LEGAL GUARANTEE

Minimum two-year legal guarantee protection for goods sold in the European Union.

Consumers can claim their rights under the legal guarantee of conformity, for example if goods:

  • do not match the description;
  • do not function as intended.

Sellers are liable for any lack of conformity which existed when the goods were delivered, and which becomes apparent within the legal guarantee period. Sellers in such a situation are required to offer:

  • free repair or free replacement;
  • in some cases, a price reduction or full reimbursement.

Some countries have a longer legal guarantee period. For second-hand goods, a shorter period may apply, but not less than one year.

For more information on your rights in a specific country, scan the QR code below or ask the seller.

europa.eu/youreurope/guarantees

What to do if you receive non-conforming goods:

  1. Contact the seller as soon as possible to report the issue;
  2. Provide proof of purchase, such as a receipt, invoice, or bank statement.

Sellers and producers may also offer commercial guarantees, which apply independently from the legal guarantee. For example, you may see this GARAN label representing a commercial guarantee of durability offered by the producer at no additional cost and covering the entire good.

Code
13501
Sales unit
box
44,77 lei37,00 lei + VAT

Purple haematology tubes with a plastic tube, a pre-measured vacuum and a sterile interior.

All tubes have a leak-proof cap to protect against direct or aerosol contamination. The stopper diaphragm is made of soft rubber to prevent puncture incidents.

  • Packaging: 100 pcs/box - 1000 pcs/carton.
  • Vol.: 1 ml
  • Dimensions: 13x75 mm
  • Type: purple cap

KIMA Vacutest tubes are made of polyethylene terephthalate (PET), a transparent material that allows visual inspection of blood and other biological fluids. The tubes resist mechanical impact, centrifugation and cracking if accidentally dropped during use.

Standard tube dimensions:

  • 13x75 mm
  • 13x100 mm
  • 16x100 mm

To improve the quality of coagulation test results, Vacutest KIMA produces tubes with thicker walls (special Vacutest IN technology). Vacutest IN tubes allow blood to reach a higher level in the tube than standard tubes of a similar volume, further preventing possible platelet activation.

A special transparent polypropylene label covering the full height of the tube prevents evaporation of the sodium citrate buffer solution, maintaining a blood:anticoagulant ratio of 9:1 throughout a long shelf life of up to 12 months.

This patented combination of Vacutest IN technology and a transparent polypropylene label guarantees the reliability of laboratory tests.

Cap / Stopper

The tube cap consists of a pierceable butyl rubber stopper and an outer plastic cap. The stopper has a recess at the puncture site to protect the operator from possible contact with blood.

The outer cap is made from polyethylene and protects against aerosols and splashes, prevents operator contact with the rubber stopper and allows easy recapping.

The special shape of the outer cap allows the same holder to be used for tubes with cap diameters of 13 mm and 16 mm.

Stopper colour coding complies with ISO 6710

Blue: coagulation tests/investigations Green: plasma tests/investigations in clinical chemistry and immunology
Black: determination of erythrocyte sedimentation rate (ESR) Purple: whole blood tests/investigations in haematology and immunology
Red, Yellow: serum tests/investigations in clinical chemistry, serology and immunology

Grey: glucose testing (blood glucose)

Blood collection procedure

When multiple blood samples need to be collected from a single patient, the specific blood collection procedure recommended by CLSI (Clinical and Laboratory Standards Institute) must be strictly followed to eliminate any possibility of cross-contamination of samples with tube contents.

Caution!

Because red-cap tubes contain a clot activator (silicon dioxide), the blood collection procedure begins with a more sensitive sample for coagulation studies in blue-cap tubes. When using butterfly blood collection needles, some blood remains in the catheter, which can alter the blood/anticoagulant ratio, especially when blood is collected into a sodium citrate tube. To obtain reliable coagulation test results, the first tube must be discarded. Tests are performed using a second tube. The discarded tube can be either a tube without additives (white cap)* or a coagulation tube.

Filling the tubes

The measured vacuum ensures that the tube fills with a precisely defined blood volume. For additional blood volume control, each tube has a level mark on its label.

In accordance with international ISO, EN and CLSI recommendations, a filling tolerance of +/- 10% relative to the fill-level mark on the label is permitted.

Sample homogenisation / mixing

After blood collection, the tube contents must be mixed thoroughly to prevent clot formation and partial blood coagulation.

Caution! All tubes must be mixed, including those containing a clot activator.

Sample storage and transport

The storage time for samples collected from patients depends on the type of investigation/test and the stability of the specific analytes.

Centrifugation

Samples requiring preliminary centrifugation must be placed in the centrifuge no later than 2 hours after collection.

Customer experience

What customers say about Profi pentru Sănătate

Reviews of the company and its services, published on Bizoo.

5,00out of 5, based on 6 reviews
View the Bizoo profile ↗
  • acum 3 ani

    Promptitudine

    Produsele prezentate sunt conforme cu cele comandate, calitatea produselor este la un nivel inalt, livrarea lor este una sigura si rapida.

    Tache M.
  • acum 3 ani

    Promptitudine

    Produsele prezentate sunt conforme cu cele comandate, livrea este rapida si sigura, calitatea este la un nivel inalt.

    Tache M.
  • acum 3 ani

    Usor de comandat!

    Mi-a placut mult faptul ca gasesc toate produsele intr-un singur loc. La fel si procedura de procesare a comenzii - usor de navigat si serviciul de livrare este foarte rapid.

    Andrascu G.
  • acum 3 ani

    Calitate la preț competitiv

    Lucrez la o companie care folosește multe produse achiziționate de la Profi Pentru Sănătate și pot sa va spun ca sunt de calitate la prețuri competitive. Da, cu toată încrederea, recomand produsele comercializate de aceasta companie.

    Oana S.
  • acum 3 ani

    Seriozitate,promptitudine si preturi OK!

    Seriozitate,promptitudine si preturi foarte bune

    Gabriel S.
  • acum 3 ani

    Livrare rapidă, produse conforme

    Am avut o experiență bună, produsele s-au livrat de pe o zi pe alta și au respectat toate criteriile de calitate.

    Alexandru A.

Reviews published on Bizoo. These reviews concern the company, not this product.

Product reviews are only allowed from accounts with an order for this product in "Processing" or "Completed" status, verified in WooCommerce. Our team moderates reviews before they are published. Bizoo reviews are about the company and its services, separately.

Made-to-order products based on your needs

Tell us which product you need and we will look for it with the manufacturers we work with.

Request by email

From the same category

Products from this product's categories, in a fixed catalogue order. Being in the same category does not confirm equivalence or compatibility.

Blue cap for serum tubes

In stockDelivery in 24–48h

75,02 lei VAT incl.62,00 lei + VAT

75,02 lei/bag · 0,08 lei/pc (1000 pcs)

Code 112

-2%

Vacutest Kima ESR tube with sodium citrate, 1.6 ml, 12 × 118 mm

In stockDelivery in 24–48h

73,57 lei VAT incl.60,80 lei + VATYou save 2,09 lei VAT incl. (2%)Lowest price in the 30 days before the discount: 75,66 lei VAT incl.

73,57 lei/bag · 100 pcs/box

Code 14250